Official ICT switch settings
A6/V6-MUP8 DIP switch settings
This is the MXP + USD build. The units we supply are configured for US dollars, so the denominations and switch positions below will not match a USD machine. Call (877) 922-6707 or send us a photo of the unit label and we will send you the right sheet.
Every switch function from ICT’s own setting sheet (part number SWAMU840-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
DIP switch tables
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
|---|---|---|---|---|---|---|---|---|
| Reject MXP 20 & USD 1 | ON | not used | not used | not used | not used | not used | not used | not used |
| Accept MXP 20 & USD 1factory default | OFF | not used | not used | not used | not used | not used | not used | not used |
| Reject MXP 50 & USD 5 | not used | ON | not used | not used | not used | not used | not used | not used |
| Accept MXP 50 & USD 5factory default | not used | OFF | not used | not used | not used | not used | not used | not used |
| Reject MXP 100 & USD 10 | not used | not used | ON | not used | not used | not used | not used | not used |
| Accept MXP 100 & USD 10factory default | not used | not used | OFF | not used | not used | not used | not used | not used |
| Reject MXP 200 & USD 20 | not used | not used | not used | ON | not used | not used | not used | not used |
| Accept MXP 200 & USD 20factory default | not used | not used | not used | OFF | not used | not used | not used | not used |
| Accept Mexico Pesos and US Dollars (Note 1) | not used | not used | not used | not used | ON | not used | not used | not used |
| Accept Mexico Pesos Only (Note 1)factory default | not used | not used | not used | not used | OFF | not used | not used | not used |
| Reserved | not used | not used | not used | not used | not used | ON | not used | not used |
| Reservedfactory default | not used | not used | not used | not used | not used | OFF | not used | not used |
| Harness Disable | not used | not used | not used | not used | not used | not used | ON | not used |
| Harness Enablefactory default | not used | not used | not used | not used | not used | not used | OFF | not used |
| Inhibit Active High | not used | not used | not used | not used | not used | not used | not used | ON |
| Inhibit Active Lowfactory default | not used | not used | not used | not used | not used | not used | not used | OFF |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| 1 pulse / MXP 10factory default | OFF | OFF | not used | not used |
| 2 pulse / MXP 10 | ON | OFF | not used | not used |
| 5 pulse / MXP 10 | OFF | ON | not used | not used |
| 10 pulse / MXP 10 | ON | ON | not used | not used |
| Interface Timing Conversion: 50ms on / 50ms offfactory default | not used | not used | OFF | OFF |
| Interface Timing Conversion: 60ms on / 300ms off | not used | not used | ON | OFF |
| Interface Timing Conversion: 30ms on / 50ms off | not used | not used | OFF | ON |
| Interface Timing Conversion: 150ms on / 150ms off | not used | not used | ON | ON |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Credit-Pulse Normal HIGHfactory default | ON | not used | not used | not used |
| Credit-Pulse Normal LOW | OFF | not used | not used | not used |
| Pulse Modefactory default | not used | ON | not used | not used |
| RS232 Interface | not used | OFF | not used | not used |
| Reserved | not used | not used | ON | not used |
| Reservedfactory default | not used | not used | OFF | not used |
| Reserved | not used | not used | not used | ON |
| Reservedfactory default | not used | not used | not used | OFF |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Scaling Factor (SF) = 100, Decimal Point Position (DPP) = 2factory default | ON | not used | not used | not used |
| Scaling Factor (SF) = 1, Decimal Point Position (DPP) = 0 | OFF | not used | not used | not used |
| Reserved | not used | ON | not used | not used |
| M.D.B Interfacefactory default | not used | OFF | not used | not used |
| Reserved | not used | not used | ON | not used |
| Reservedfactory default | not used | not used | OFF | not used |
| Reserved | not used | not used | not used | ON |
| Reservedfactory default | not used | not used | not used | OFF |
| Bill value | MDB (MXP) | MDB (USD) |
|---|---|---|
| BV1 | — | USD 1 |
| BV2 | MXP 20 | — |
| BV3 | MXP 50 | USD 5 |
| BV4 | MXP 100 | USD 10 |
| BV5 | MXP 200 | USD 20 |
Before you power up
- Factory configuration has all switches in the OFF position.
- For Accepting US Dollars, make sure you have dip 5 set to ON position. (Exchange rate on USD to MXP is 1:10)
- Reset the bill acceptor after setting the dip switch.
- SW7 and SW8 of the 8-switch DIP and the 4-switch DIP are for pulse protocol only.
Not the sheet for your unit?
ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.