Official ICT switch settings

BRV-MXN9(MXN5+USD4) DIP switch settings

This is the MXN + USD build. The units we supply are configured for US dollars, so the denominations and switch positions below will not match a USD machine. Call (877) 922-6707 or send us a photo of the unit label and we will send you the right sheet.

Every switch function from ICT’s own setting sheet (part number SWCUMX90500-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

DIP switch tables

BRV dip-switch settings and functions
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject USD 1ONnot usednot usednot usednot usednot usednot usednot used
Accept USD 1factory defaultOFFnot usednot usednot usednot usednot usednot usednot used
Reject MXN 50 & USD 5not usedONnot usednot usednot usednot usednot usednot used
Accept MXN 50 & USD 5factory defaultnot usedOFFnot usednot usednot usednot usednot usednot used
Reject MXN 100 & USD 10not usednot usedONnot usednot usednot usednot usednot used
Accept MXN 100 & USD 10factory defaultnot usednot usedOFFnot usednot usednot usednot usednot used
Reject MXN 200/500 & USD 20not usednot usednot usedONnot usednot usednot usednot used
Accept MXN 200/500 & USD 20factory defaultnot usednot usednot usedOFFnot usednot usednot usednot used
Reject MXN 20not usednot usednot usednot usedONnot usednot usednot used
Accept MXN 20factory defaultnot usednot usednot usednot usedOFFnot usednot usednot used
Normalfactory defaultnot usednot usednot usednot usednot usedOFFOFFnot used
Load Banknote to Recyclenot usednot usednot usednot usednot usedONOFFnot used
Load Banknote to Stackernot usednot usednot usednot usednot usedOFFONnot used
Unload Banknote to Stackernot usednot usednot usednot usednot usedONONnot used
Accept Mexico Pesos and US Dollars (Note.3)not usednot usednot usednot usednot usednot usednot usedON
Accept Mexico Pesos Only (Note.3)factory defaultnot usednot usednot usednot usednot usednot usednot usedOFF
MDB Mode
FunctionSW1SW2SW3SW4
ReservedONnot usednot usednot used
Reservedfactory defaultOFFnot usednot usednot used
Reservednot usedONnot usednot used
Reservedfactory defaultnot usedOFFnot usednot used
Reservednot usednot usedONnot used
Reservedfactory defaultnot usednot usedOFFnot used
Virtual MDB Recycler Function (Note.5)factory defaultnot usednot usednot usedON
Standard MDB Recycler Functionnot usednot usednot usedOFF
JPSTD Dummy Mode
FunctionSW1SW2SW3SW4
255 Bank Note Limitation Per Transactionfactory defaultONONONnot used
1 Bank Note Limitation Per TransactionOFFOFFOFFnot used
2 Bank Note Limitation Per TransactionONOFFOFFnot used
3 Bank Note Limitation Per TransactionOFFONOFFnot used
4 Bank Note Limitation Per TransactionONONOFFnot used
5 Bank Note Limitation Per TransactionOFFOFFONnot used
6 Bank Note Limitation Per TransactionONOFFONnot used
7 Bank Note Limitation Per TransactionOFFONONnot used
No Refund After the Dealnot usednot usednot usedON
Refund After the Dealfactory defaultnot usednot usednot usedOFF
Interface Settings: 2 (ICT-BC)
FunctionSW5SW6SW7SW8
ReservedONnot usednot usednot used
Reservedfactory defaultOFFnot usednot usednot used
Connect with MDB Connectornot usednot usedONnot used
Connect with RS232 Connectorfactory defaultnot usednot usedOFFnot used
MDB Modenot usednot usedOFFOFF
JPSTD Dummy Modenot usednot usedOFFON
Reservednot usednot usedONOFF
ICT-BC Modefactory defaultnot usednot usedONON
Interface Settings: 2 (JPSTD Dummy)
FunctionSW5SW6SW7SW8
Escrow (JPSTD Dummy Mode)ONnot usednot usednot used
No Escrow (JPSTD Dummy Mode)factory defaultOFFnot usednot usednot used
Reservednot usedONnot usednot used
Reservedfactory defaultnot usedOFFnot usednot used
MDB Modenot usednot usedOFFOFF
JPSTD Dummy Modefactory defaultnot usednot usedOFFON
Reservednot usednot usedONOFF
ICT-BC Modenot usednot usedONON
Interface Settings: 2 (MDB)
FunctionSW5SW6SW7SW8
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory defaultONnot usednot usednot used
Scaling Factor (SF) = 1; Decimal Point Position (DPP) = 0OFFnot usednot usednot used
Reservednot usedONnot usednot used
Reservedfactory defaultnot usedOFFnot usednot used
MDB Modefactory defaultnot usednot usedOFFOFF
JPSTD Dummy Modenot usednot usedOFFON
Reservednot usednot usedONOFF
ICT-BC Modenot usednot usedONON
Currency Assign Data
Bill valueJPSTD DummyICT-BCMDBRecycler banknoteInventory
BV1MXN 20MXN 20MXN 20MXN 2025 pcs
BV2MXN 50MXN 50MXN 50MXN 5025 pcs
BV3MXN 100MXN 100MXN 100MXN 10025 pcs
BV4MXN 200MXN 200MXN 200MXN 20025 pcs
BV5MXN 500MXN 500MXN 500MXN 50025 pcs
BV6USD 1USD 1USD 1USD 125 pcs
BV7USD 5USD 5USD 5USD 525 pcs
BV8USD 10USD 10USD 10USD 1025 pcs
BV9USD 20USD 20USD 20USD 2025 pcs
Before you power up
  • (1) After setting dip switch of the credit pulses, you should reset the bill acceptor again.
  • (2) Please reset the bill acceptor after set the dip switch.
  • (3) For Accepting US Dollars, make sure you have dip 8 set to ON position. (* Exchange Rate on USD to MXN is 1:18 for MDB, ICT-BC Mode)
  • (4) Calibration card is needed.
  • (5) Recycled Banknote represents virtual MDB coin type.

Not the sheet for your unit?