BRV-PUN5(PEN3+USD2) DIP switch settings

This is the PEN + USD build. The units we supply are configured for US dollars, so the denominations and switch positions below will not match a USD machine. Call (877) 922-6707 or send us a photo of the unit label and we will send you the right sheet.

Every switch function from ICT’s own setting sheet (part number SWCUPU510-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

DIP switch tables

BRV Option Switch Settings: 1 (ICT-BC/MDB/VCCS Dummy) — BRV dip-switch settings and functions
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject PEN 10ONnot usednot usednot usednot usednot usednot usednot used
Accept PEN 10factory defaultOFFnot usednot usednot usednot usednot usednot usednot used
Reject PEN 20not usedONnot usednot usednot usednot usednot usednot used
Accept PEN 20factory defaultnot usedOFFnot usednot usednot usednot usednot usednot used
Reject PEN 50not usednot usedONnot usednot usednot usednot usednot used
Accept PEN 50factory defaultnot usednot usedOFFnot usednot usednot usednot usednot used
Reject USD 1 (Note.3)not usednot usednot usedONnot usednot usednot usednot used
Accept USD 1 (Note.3)factory defaultnot usednot usednot usedOFFnot usednot usednot usednot used
Reject USD 5 (Note.3)not usednot usednot usednot usedONnot usednot usednot used
Accept USD 5 (Note.3)factory defaultnot usednot usednot usednot usedOFFnot usednot usednot used
Normalfactory defaultnot usednot usednot usednot usednot usedOFFOFFnot used
Load Banknote to Recyclenot usednot usednot usednot usednot usedONOFFnot used
Load Banknote to Stackernot usednot usednot usednot usednot usedOFFONnot used
Unload Banknote to Stackernot usednot usednot usednot usednot usedONONnot used
Reservednot usednot usednot usednot usednot usednot usednot usedON
Reservedfactory defaultnot usednot usednot usednot usednot usednot usednot usedOFF
BRV Option Switch Settings: 1 (MDB Mode)
FunctionSW1SW2SW3SW4
ReservedONnot usednot usednot used
Reservedfactory defaultOFFnot usednot usednot used
Reservednot usedONnot usednot used
Reservedfactory defaultnot usedOFFnot usednot used
Reservednot usednot usedONnot used
Reservedfactory defaultnot usednot usedOFFnot used
Virtual MDB Recycler Functionnot usednot usednot usedON
Standard MDB Recycler Functionfactory defaultnot usednot usednot usedOFF
BRV Option Switch Settings: 1 (VCCS Dummy Mode)
FunctionSW1SW2SW3SW4
255 Bank Note Limitation Per Transactionfactory defaultONONONnot used
1 Bank Note Limitation Per TransactionOFFOFFOFFnot used
2 Bank Note Limitation Per TransactionONOFFOFFnot used
3 Bank Note Limitation Per TransactionOFFONOFFnot used
4 Bank Note Limitation Per TransactionONONOFFnot used
5 Bank Note Limitation Per TransactionOFFOFFONnot used
6 Bank Note Limitation Per TransactionONOFFONnot used
7 Bank Note Limitation Per TransactionOFFONONnot used
No Refund After the Dealnot usednot usednot usedON
Refund After the Dealfactory defaultnot usednot usednot usedOFF
Interface Settings: 2 (ICT-BC)
FunctionSW5SW6SW7SW8
ReservedONnot usednot usednot used
Reservedfactory defaultOFFnot usednot usednot used
Connect with MDB Connectornot usedONnot usednot used
Connect with RS232 Connectorfactory defaultnot usedOFFnot usednot used
MDB Modenot usednot usedOFFOFF
VCCS Dummy Modenot usednot usedOFFON
Reservednot usednot usedONOFF
ICT-BC Modefactory defaultnot usednot usedONON
Interface Settings: 2 (VCCS Dummy)
FunctionSW5SW6SW7SW8
Escrow (VCCS Dummy Mode)ONnot usednot usednot used
No Escrow (VCCS Dummy Mode)factory defaultOFFnot usednot usednot used
Reservednot usedONnot usednot used
Reservedfactory defaultnot usedOFFnot usednot used
MDB Modenot usednot usedOFFOFF
VCCS Dummy Modefactory defaultnot usednot usedOFFON
Reservednot usednot usedONOFF
ICT-BC Modefactory defaultnot usednot usedONON
Interface Settings: 2 (MDB)
FunctionSW5SW6SW7SW8
Scaling Factor (SF) = 100, Decimal Point Position (DPP) = 2factory defaultONnot usednot usednot used
Scaling Factor (SF) = 1, Decimal Point Position (DPP) = 0OFFnot usednot usednot used
Reservednot usedONnot usednot used
Reservedfactory defaultnot usedOFFnot usednot used
MDB Modefactory defaultnot usednot usedOFFOFF
VCCS Dummy Modenot usednot usedOFFON
Reservednot usednot usedONOFF
ICT-BC Modenot usednot usedONON
Currency Assign Data
Bill valueVCCS DummyICT-BCMDB
BV1PEN 10PEN 10PEN 10
BV2PEN 20PEN 20PEN 20
BV3PEN 50PEN 50PEN 50
BV4USD 1USD 1USD 1
BV5USD 5USD 5USD 5
Before you power up
  • (1) After setting dip switch of the credit pulses, you should reset the bill acceptor again.
  • (2) Please reset the bill acceptor after set the dip switch.
  • (3) Exchange Rate on USD to PEN is 1:3 for MDB Mode.
  • (4) Calibrate card.
  • (5) Recycked Banknote represents virtual MDB coin type.