Official ICT switch settings
L70-USD6 DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWAFUS6300-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
DIP switch tables
| Function | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 | SW9 | SW10 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 Pulse / USD 1factory default | OFF | OFF | OFF | not used | not used | not used | not used | not used | not used | not used |
| 2 Pulses / USD 1 | OFF | OFF | ON | not used | not used | not used | not used | not used | not used | not used |
| 3 Pulses / USD 1 | OFF | ON | OFF | not used | not used | not used | not used | not used | not used | not used |
| 4 Pulses / USD 1 | OFF | ON | ON | not used | not used | not used | not used | not used | not used | not used |
| 5 Pulses / USD 1 | ON | OFF | OFF | not used | not used | not used | not used | not used | not used | not used |
| 10 Pulses / USD 1 | ON | OFF | ON | not used | not used | not used | not used | not used | not used | not used |
| 20 Pulses / USD 1 | ON | ON | OFF | not used | not used | not used | not used | not used | not used | not used |
| 100 Pulses / USD 1 | ON | ON | ON | not used | not used | not used | not used | not used | not used | not used |
| Fast output Pulse (Lo = 30ms, Hi = 50ms) | not used | not used | not used | ON | not used | not used | not used | not used | not used | not used |
| Slow output Pulse (Lo = 50ms, Hi = 100ms)factory default | not used | not used | not used | OFF | not used | not used | not used | not used | not used | not used |
| Inhibit level Active Low | not used | not used | not used | not used | ON | not used | not used | not used | not used | not used |
| Inhibit level Active Highfactory default | not used | not used | not used | not used | OFF | not used | not used | not used | not used | not used |
| Accept USD 1factory default | not used | not used | not used | not used | not used | ON | not used | not used | not used | not used |
| Reject USD 1 | not used | not used | not used | not used | not used | OFF | not used | not used | not used | not used |
| Accept USD 5factory default | not used | not used | not used | not used | not used | not used | ON | not used | not used | not used |
| Reject USD 5 | not used | not used | not used | not used | not used | not used | OFF | not used | not used | not used |
| Accept USD 10factory default | not used | not used | not used | not used | not used | not used | not used | ON | not used | not used |
| Reject USD 10 | not used | not used | not used | not used | not used | not used | not used | OFF | not used | not used |
| Accept USD 20factory default | not used | not used | not used | not used | not used | not used | not used | not used | ON | not used |
| Reject USD 20 | not used | not used | not used | not used | not used | not used | not used | not used | OFF | not used |
| Accept USD 50 & 100factory default | not used | not used | not used | not used | not used | not used | not used | not used | not used | ON |
| Reject USD 50 & 100 | not used | not used | not used | not used | not used | not used | not used | not used | not used | OFF |
- DIP switches 1 to 5 are only for Pulse mode.
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Reservedfactory default | ON | not used | not used | not used |
| Reserved | OFF | not used | not used | not used |
| Pulse Modefactory default | not used | ON | OFF | not used |
| RS232 A0 Mode | not used | ON | ON | not used |
| V2.2 Mode | not used | OFF | ON | not used |
| Reserved | not used | OFF | OFF | not used |
| Disable Inverse Mode | not used | not used | not used | ON |
| Enable Inverse Modefactory default | not used | not used | not used | OFF |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Reservedfactory default | ON | not used | not used | not used |
| Reserved | OFF | not used | not used | not used |
| Pulse Mode | not used | ON | OFF | not used |
| RS232 A0 Modefactory default | not used | ON | ON | not used |
| V2.2 Mode | not used | OFF | ON | not used |
| Reserved | not used | OFF | OFF | not used |
| Disable Inverse Mode | not used | not used | not used | ON |
| Enable Inverse Modefactory default | not used | not used | not used | OFF |
| Function | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Reserved | ON | not used | not used | not used |
| Reservedfactory default | OFF | not used | not used | not used |
| Pulse Mode | not used | ON | OFF | not used |
| RS232 A0 Mode | not used | ON | ON | not used |
| V2.2 Modefactory default | not used | OFF | ON | not used |
| Reserved | not used | OFF | OFF | not used |
| Disable Inverse Mode | not used | not used | not used | ON |
| Enable Inverse Modefactory default | not used | not used | not used | OFF |
| Bill value | Pulse | RS232 A0 | V2.2 |
|---|---|---|---|
| BV1 | USD 1 | USD 1 | USD 1 |
| BV2 | USD 5 | — | USD 5 |
| BV3 | USD 10 | USD 5 | USD 10 |
| BV4 | USD 20 | USD 10 | USD 20 |
| BV5 | USD 50 | USD 20 | USD 50 |
| BV6 | USD 100 | USD 50 | USD 100 |
| BV7 | — | USD 100 | — |
Before you power up
- Please reset the bill acceptor after any changes on DIP switch.
Not the sheet for your unit?
ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.