Official ICT switch settings
USD6 DIP switch settings
Every switch function from ICT’s own setting sheet (part number SWV2US610-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.
DIP switch tables
| Function | SW1 | SW2 |
|---|---|---|
| Accepted banknotes -> stacketfactory default | OFF | OFF |
| Accepted banknotes -> Recycler escrow buffer area. (Bill acceptor will disable while recycler is full.) | ON | OFF |
| Banknote(s) dispensing mode. | OFF | ON |
| Recycler -> Stacker. (Empty Recycler mode.) | ON | ON |
| Function | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 | SW9 | SW10 |
|---|---|---|---|---|---|---|---|---|
| Normalfactory default | ON | not used | not used | not used | not used | not used | not used | not used |
| Diagnostic mode | OFF | not used | not used | not used | not used | not used | not used | not used |
| Optical anti-fishing malfunction, BA will be still in working order | not used | ON | not used | not used | not used | not used | not used | not used |
| BA will stop to work when it acknowledges Optical anti-fishing malfunctionfactory default | not used | OFF | not used | not used | not used | not used | not used | not used |
| ICT mode | not used | not used | ON | not used | not used | not used | not used | not used |
| RS232 B1 modefactory default | not used | not used | OFF | not used | not used | not used | not used | not used |
| Accept USD 1 & 5factory default | not used | not used | not used | ON | not used | not used | not used | not used |
| Reject USD 1 & 5 | not used | not used | not used | OFF | not used | not used | not used | not used |
| Accept USD 10 & 20factory default | not used | not used | not used | not used | ON | not used | not used | not used |
| Reject USD 10 & 20 | not used | not used | not used | not used | OFF | not used | not used | not used |
| Accept USD 50 & 100factory default | not used | not used | not used | not used | not used | ON | not used | not used |
| Reject USD 50 & 100 | not used | not used | not used | not used | not used | OFF | not used | not used |
| RS232 B1 parameters restore (Please see Note.2 for detail) | not used | not used | not used | not used | not used | not used | ON | not used |
| RS232 B1 parameters not restorefactory default | not used | not used | not used | not used | not used | not used | OFF | not used |
| Encryption MODEfactory default | not used | not used | not used | not used | not used | not used | not used | ON |
| Decrypt MODE | not used | not used | not used | not used | not used | not used | not used | OFF |
| Bill value | ccTalk | ICT |
|---|---|---|
| BV1 | USD 1 | USD 1 |
| BV2 | USD 5 | USD 5 |
| BV3 | USD 10 | USD 10 |
| BV4 | USD 20 | USD 20 |
| BV5 | USD 50 | USD 50 |
| BV6 | USD 100 | USD 100 |
Before you power up
- Please restart the bill acceptor after any changes on dip switch(s) has been made.
- Turn this dip to with restart the bill acceptor will restore RS232 B1 address to its default value of 40 and the encryption key to its default value of 123456.
Not the sheet for your unit?
ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.