Official ICT switch settings

TAO-V-MUP4(MXP2+USD2) DIP switch settings

This is the MXP + USD build. The units we supply are configured for US dollars, so the denominations and switch positions below will not match a USD machine. Call (877) 922-6707 or send us a photo of the unit label and we will send you the right sheet.

Every switch function from ICT’s own setting sheet (part number SWH5MU42000-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

DIP switch tables

TAO-V dip-switch settings and functions — Switches 1–8
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject USD 1ONnot usednot usednot usednot usednot usednot usednot used
Accept USD 1factory defaultOFFnot usednot usednot usednot usednot usednot usednot used
Reject MXP 20not usedONnot usednot usednot usednot usednot usednot used
Accept MXP 20factory defaultnot usedOFFnot usednot usednot usednot usednot usednot used
Reject MXP 50not usednot usedONnot usednot usednot usednot usednot used
Accept MXP 50factory defaultnot usednot usedOFFnot usednot usednot usednot usednot used
Reject USD 5not usednot usednot usedONnot usednot usednot usednot used
Accept USD 5factory defaultnot usednot usednot usedOFFnot usednot usednot usednot used
Reservednot usednot usednot usednot usedONnot usednot usednot used
Reservedfactory defaultnot usednot usednot usednot usedOFFnot usednot usednot used
Reservednot usednot usednot usednot usednot usedONnot usednot used
Reservedfactory defaultnot usednot usednot usednot usednot usedOFFnot usednot used
Harness Disable — BA stops working when fishingnot usednot usednot usednot usednot usednot usedONnot used
Harness Enable — Normalfactory defaultnot usednot usednot usednot usednot usednot usedOFFnot used
Inhibit Active Highnot usednot usednot usednot usednot usednot usednot usedON
Inhibit Active Lowfactory defaultnot usednot usednot usednot usednot usednot usednot usedOFF
TAO-V dip-switch settings and functions — pulse denomination bank
FunctionSW1SW2
1 pulse / MXP 10 & USD 1factory defaultOFFOFF
2 pulses / MXP 10 & USD 1ONOFF
5 pulses / MXP 10 & USD 1OFFON
10 pulses / MXP 10 & USD 1ONON
TAO-V dip-switch settings and functions — interface timing bank
FunctionSW3SW4
Interface Timing Conversion: 50ms LO / 50ms HIfactory defaultOFFOFF
Interface Timing Conversion: 60ms LO / 300ms HIONOFF
Interface Timing Conversion: 30ms LO / 50ms HIOFFON
Interface Timing Conversion: 150ms LO / 150ms HIONON
Interface Settings: 2(Pulse)
FunctionSW1SW2SW3SW4
Credit-Pulse Normal HIGHfactory defaultONnot usednot usednot used
Credit-Pulse Normal LOWOFFnot usednot usednot used
Pulse Modefactory defaultnot usedONnot usednot used
MDB Interfacenot usedOFFnot usednot used
Reservednot usednot usedONnot used
Reservedfactory defaultnot usednot usedOFFnot used
Reservednot usednot usednot usedON
Reservedfactory defaultnot usednot usednot usedOFF
Interface Settings: 2(MDB)
FunctionSW1SW2SW3SW4
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory defaultONnot usednot usednot used
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2OFFnot usednot usednot used
Pulse Modenot usedONnot usednot used
MDB Interfacefactory defaultnot usedOFFnot usednot used
Reservednot usednot usedONnot used
Reservedfactory defaultnot usednot usedOFFnot used
Reservednot usednot usednot usedON
Reservedfactory defaultnot usednot usednot usedOFF
Currency Assign Data
Bill valuePulseMDB
BV1USD 1USD 1
BV2MXP 20MXP 20
BV3MXP 50MXP 50
BV4USD 5USD 5
Before you power up
  • Default setting.
  • Use 2nd dip switch of the internal dip-switch to change different interface protocol.
  • For Accepting US Dollars Exchange Rate on USD to MXP is 1:18 for MDB Mode.