Official ICT switch settings

V7E/LX7-BUD6(BBD4+USD2) DIP switch settings

This is the BBD + USD build. The units we supply are configured for US dollars, so the denominations and switch positions below will not match a USD machine. Call (877) 922-6707 or send us a photo of the unit label and we will send you the right sheet.

Every switch function from ICT’s own setting sheet (part number SWVR6BU62000-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

DIP switch tables

V7E/LX7 Option Switch Settings: 1 (Pulse/ICT104U/MDB) — 8-switch DIP
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject BBD 2ONnot usednot usednot usednot usednot usednot usednot used
Accept BBD 2factory defaultOFFnot usednot usednot usednot usednot usednot usednot used
Reject BBD 5not usedONnot usednot usednot usednot usednot usednot used
Accept BBD 5factory defaultnot usedOFFnot usednot usednot usednot usednot usednot used
Reject BBD 10not usednot usedONnot usednot usednot usednot usednot used
Accept BBD 10factory defaultnot usednot usedOFFnot usednot usednot usednot usednot used
Reject BBD 20not usednot usednot usedONnot usednot usednot usednot used
Accept BBD 20factory defaultnot usednot usednot usedOFFnot usednot usednot usednot used
Reject USD 1not usednot usednot usednot usedONnot usednot usednot used
Accept USD 1factory defaultnot usednot usednot usednot usedOFFnot usednot usednot used
Reject USD 5not usednot usednot usednot usednot usedONnot usednot used
Accept USD 5factory defaultnot usednot usednot usednot usednot usedOFFnot usednot used
Harness Disable (Other Mode: BA stops working when fishing)not usednot usednot usednot usednot usednot usedONnot used
Harness Enable (Other Mode: Normal)factory defaultnot usednot usednot usednot usednot usednot usedOFFnot used
Inhibit Active Highnot usednot usednot usednot usednot usednot usednot usedON
Inhibit Active Lowfactory defaultnot usednot usednot usednot usednot usednot usednot usedOFF
V7E/LX7 Option Switch Settings: 1 — 4-switch DIP (pulse protocol)
FunctionSW1SW2SW3SW4
1 pulse / BBD 1factory defaultOFFOFFnot usednot used
2 pulses / BBD 1ONOFFnot usednot used
4 pulses / BBD 1OFFONnot usednot used
20 pulses / BBD 1ONONnot usednot used
Pulse Speed — 50ms LO / 50ms HIfactory defaultnot usednot usedOFFOFF
Pulse Speed — 60ms LO / 300ms HInot usednot usedONOFF
Pulse Speed — 30ms LO / 50ms HInot usednot usedOFFON
Pulse Speed — 150ms LO / 150ms HInot usednot usedONON
DIP SWITCHES SETTING: 2 (Pulse)
FunctionSW1SW2SW3SW4
Pulse Normal Highfactory defaultONnot usednot usednot used
Pulse Normal LowOFFnot usednot usednot used
Pulse Modefactory defaultnot usedONOFFnot used
ICT104U Interfacenot usedOFFONnot used
MDB Interfacenot usedONONnot used
Reservednot usedOFFOFFnot used
Accept BBD polymernot usednot usednot usedON
Accept BBD ALL (Paper & polymer)factory defaultnot usednot usednot usedOFF
DIP SWITCHES SETTING: 2 (ICT104U)
FunctionSW1SW2SW3SW4
ReservedONnot usednot usednot used
Reservedfactory defaultOFFnot usednot usednot used
Pulse Modefactory defaultnot usedONOFFnot used
ICT104U Interfacenot usedOFFONnot used
MDB Interfacenot usedONONnot used
Reservednot usedOFFOFFnot used
Accept BBD polymernot usednot usednot usedON
Accept BBD ALL (Paper & polymer)factory defaultnot usednot usednot usedOFF
DIP SWITCHES SETTING: 2 (MDB)
FunctionSW1SW2SW3SW4
Scaling Factor (SF) = 100, Decimal Point Position (DPP) = 2factory defaultONnot usednot usednot used
Scaling Factor (SF) = 1, Decimal Point Position (DPP) = 0OFFnot usednot usednot used
Pulse Modenot usedONOFFnot used
ICT104U Interfacenot usedOFFONnot used
MDB Interfacefactory defaultnot usedONONnot used
Reservednot usedOFFOFFnot used
Accept BBD polymernot usednot usednot usedON
Accept BBD ALL (Paper & polymer)factory defaultnot usednot usednot usedOFF
Currency Assign Data
Bill valueICT104UPulseMDB
BV1BBD 2BBD 2BBD 2
BV2BBD 5BBD 5BBD 5
BV3BBD 10BBD 10BBD 10
BV4BBD 20BBD 20BBD 20
BV5USD 1USD 1USD 1
BV6USD 5USD 5USD 5
Before you power up
  • (1) Default setting.
  • (2) Use 2nd and 3rd dip of the internal dip-switch to change different interface protocol.
  • (3) Remove the front cover and the dip-switch in on the CPU board.
  • (4) Exchange rate: 1 USD = 2 BBD

Not the sheet for your unit?

ICT ships the same model with different firmware and currency sets. Send us a photo of the label on the side of the acceptor and we will tell you exactly which settings apply.