V7E/LX7-XCD6 DIP switch settings

This is the USD + XCD build. The units we supply are configured for US dollars, so the denominations and switch positions below will not match a USD machine. Call (877) 922-6707 or send us a photo of the unit label and we will send you the right sheet.

Every switch function from ICT’s own setting sheet (part number SWR6XC60100-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

DIP switch tables

V7E/LX7 Option Switch Settings: 1 (Pulse/ICT104V/ICT104U/MDB) — 8-switch DIP
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject XCD 5 & USD 1ONnot usednot usednot usednot usednot usednot usednot used
Accept XCD 5 & USD 1factory defaultOFFnot usednot usednot usednot usednot usednot usednot used
Reject XCD 10 & USD 5not usedONnot usednot usednot usednot usednot usednot used
Accept XCD 10 & USD 5factory defaultnot usedOFFnot usednot usednot usednot usednot usednot used
Reject XCD 20 & USD 10not usednot usedONnot usednot usednot usednot usednot used
Accept XCD 20 & USD 10factory defaultnot usednot usedOFFnot usednot usednot usednot usednot used
Reservednot usednot usednot usedONnot usednot usednot usednot used
Reservedfactory defaultnot usednot usednot usedOFFnot usednot usednot usednot used
Reservednot usednot usednot usednot usedONnot usednot usednot used
Reservedfactory defaultnot usednot usednot usednot usedOFFnot usednot usednot used
Reservednot usednot usednot usednot usednot usedONnot usednot used
Reservedfactory defaultnot usednot usednot usednot usednot usedOFFnot usednot used
Pulse Mode / Other Modenot usednot usednot usednot usednot usednot usednot usednot used
Harness Disable — BA stopped working when fishingnot usednot usednot usednot usednot usednot usedONnot used
Harness Enable — Normalfactory defaultnot usednot usednot usednot usednot usednot usedOFFnot used
Inhibit Active Highnot usednot usednot usednot usednot usednot usednot usedON
Inhibit Active Lowfactory defaultnot usednot usednot usednot usednot usednot usednot usedOFF
  • Dip Switch 1 to 5 are only for Pulse mode.
  • Pulse working with $1 USD = $2 XCD.
  • MDB working with $1 USD = $2.5 XCD.
V7E/LX7 Option Switch Settings: 1 (Pulse/ICT104V/ICT104U/MDB) — 4-switch pulse setting
FunctionSW1SW2SW3SW4
1 pulse / XCD 1factory defaultOFFOFFnot usednot used
5 pulses / XCD 1ONOFFnot usednot used
10 pulses / XCD 1OFFONnot usednot used
25 pulses / XCD 1ONONnot usednot used
Pulse Speed: 50ms LO / 50ms HIfactory defaultnot usednot usedOFFOFF
Pulse Speed: 60ms LO / 300ms HInot usednot usedONOFF
Pulse Speed: 30ms LO / 50ms HInot usednot usedOFFON
Pulse Speed: 150ms LO / 150ms HInot usednot usedONON
DIP SWITCHES SETTING: 2 (Pulse)
FunctionSW1SW2SW3SW4
Credit-Pulse Normal HIGHfactory defaultONnot usednot usednot used
Credit-Pulse Normal LOWOFFnot usednot usednot used
Pulse Modefactory defaultnot usedONOFFnot used
ICT104U Interfacenot usedOFFOFFnot used
ICT104V Interfacenot usedOFFONnot used
MDB Interfacenot usedONONnot used
Reservednot usednot usednot usedON
Reservedfactory defaultnot usednot usednot usedOFF
DIP SWITCHES SETTING: 2 (ICT104U)
FunctionSW1SW2SW3SW4
Reservedfactory defaultONnot usednot usednot used
ReservedOFFnot usednot usednot used
Pulse Modenot usedONOFFnot used
ICT104U Interfacefactory defaultnot usedOFFOFFnot used
ICT104V Interfacenot usedOFFONnot used
MDB Interfacenot usedONONnot used
Reservednot usednot usednot usedON
Reservedfactory defaultnot usednot usednot usedOFF
DIP SWITCHES SETTING: 2 (ICT104V)
FunctionSW1SW2SW3SW4
Reservedfactory defaultONnot usednot usednot used
ReservedOFFnot usednot usednot used
Pulse Modenot usedONOFFnot used
ICT104U Interfacenot usedOFFOFFnot used
ICT104V Interfacefactory defaultnot usedOFFONnot used
MDB Interfacenot usedONONnot used
Reservednot usednot usednot usedON
Reservedfactory defaultnot usednot usednot usedOFF
DIP SWITCHES SETTING: 2 (MDB)
FunctionSW1SW2SW3SW4
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory defaultONnot usednot usednot used
Scaling Factor (SF) = 1; Decimal Point Position (DPP) = 1OFFnot usednot usednot used
Pulse Modenot usedONOFFnot used
ICT104U Interfacenot usedOFFOFFnot used
ICT104V Interfacenot usedOFFONnot used
MDB Interfacefactory defaultnot usedONONnot used
Reservednot usednot usednot usedON
Reservedfactory defaultnot usednot usednot usedOFF
Currency Assign Data
Bill valueICT104VICT104UPulseMDB
BV1XCD 5XCD 5XCD 5XCD 5
BV2XCD 10XCD 10XCD 10XCD 10
BV3XCD 20XCD 20XCD 20XCD 20
BV4USD 1USD 1USD 1USD 1
BV5USD 5USD 5USD 5USD 5
BV6USD 10USD 10USD 10USD 10
Before you power up
  • Please reset the bill acceptor after any changes on Dip switch.