Official ICT switch settings

XBA-UCD7(USD4+CAD3) DIP switch settings

This is the CAD + USD build. The units we supply are configured for US dollars, so the denominations and switch positions below will not match a USD machine. Call (877) 922-6707 or send us a photo of the unit label and we will send you the right sheet.

Every switch function from ICT’s own setting sheet (part number SWT8UC720-R), transcribed into tables you can read on a phone at the machine. Rows marked factory default are how the unit ships.

DIP switch tables

XBA-UCD7 Option Switch Settings: primary settings
FunctionSW1SW2SW3SW4SW5SW6SW7SW8
Reject USD 1 & USD / CAD 5ONnot usednot usednot usednot usednot usednot usednot used
Accept USD 1 & USD / CAD 5factory defaultOFFnot usednot usednot usednot usednot usednot usednot used
Reject USD / CAD 10not usedONnot usednot usednot usednot usednot usednot used
Accept USD / CAD 10factory defaultnot usedOFFnot usednot usednot usednot usednot usednot used
Reject USD / CAD 20not usednot usedONnot usednot usednot usednot usednot used
Accept USD / CAD 20factory defaultnot usednot usedOFFnot usednot usednot usednot usednot used
Accept USD+CADfactory defaultnot usednot usednot usedOFFOFFnot usednot usednot used
Accept USDnot usednot usednot usedOFFONnot usednot usednot used
Accept CADnot usednot usednot usedONOFFnot usednot usednot used
Reservednot usednot usednot usedONONnot usednot usednot used
Disable Bill Reject 4 Times BA Stop By 30 Secnot usednot usednot usednot usednot usedONnot usednot used
Enable Bill Reject 4 Times BA Stop By 30 Secfactory defaultnot usednot usednot usednot usednot usedOFFnot usednot used
Stack Banknote when Power-upnot usednot usednot usednot usednot usednot usedONnot used
Reject Banknote when Power-upfactory defaultnot usednot usednot usednot usednot usednot usedOFFnot used
Reservednot usednot usednot usednot usednot usednot usednot usedON
Reservedfactory defaultnot usednot usednot usednot usednot usednot usednot usedOFF
  • This dip switch is located at the side of XBA.
XBA-UCD7 (Pulse/MDB/ICT): upper interface settings
FunctionSW1SW2SW3SW4
Inhibit Active HIGHONnot usednot usednot used
Inhibit Active LOWfactory defaultOFFnot usednot usednot used
Colorful lightnot usedOFFOFFnot used
The green light flashesfactory defaultnot usedOFFONnot used
Reservednot usedONOFFnot used
No lightnot usedONONnot used
Reservednot usednot usednot usedON
Reservedfactory defaultnot usednot usednot usedOFF
XBA-UCD7 (Pulse/MDB/ICT): Pulse Mode selection
FunctionSW1
Credit-Pulse Normal HIGHfactory defaultON
Credit-Pulse Normal LOWOFF
Pulse Modefactory defaultON
Other ModeOFF
XBA-UCD7 (Pulse/MDB/ICT): MDB / ICT104V option settings
FunctionSW2
Scaling Factor (SF) = 100; Decimal Point Position (DPP) = 2factory defaultON
Scaling Factor (SF) = 1; Decimal Point Position (DPP) = 0OFF
Connect with coin changerfactory defaultON
Connect with ICT JPSTD Converter boardOFF
XBA-UCD7 (Pulse/MDB/ICT): mode and pulse-count selection
FunctionSW1SW2
1 pulse / USD&CAD 1 / MDB Modefactory defaultOFFOFF
2 pulses / USD&CAD 1 / ICT002U ModeOFFON
4 pulses / USD&CAD 1 / ICT104U ModeONOFF
20 pulses / USD&CAD 1 / ICT104V ModeONON
Currency Assign Data
Bill valueICT002UICT104UICT104VPulseMDB
BV1USD 1USD 1USD 1USD 1USD 1
BV2USD 5USD 5USD 5USD 5USD 5
BV3USD 10USD 10USD 10USD 10USD 10
BV4USD 20USD 20USD 20USD 20USD 20
BV5CAD 5CAD 5CAD 5CAD 5CAD 5
BV6CAD 10CAD 10CAD 10CAD 10CAD 10
BV7CAD 20CAD 20CAD 20CAD 20CAD 20
Before you power up
  • This dip switch is located at the side of XBA.
  • This dip switch is located on the CPU board, remove the CPU board cover first.
  • After setting dip switch of the credit pulses, you should reset the bill acceptor again.
  • Note: 1. Calibration card is needed.
  • 2. 1 USD = 1 CAD.